HID Data Sheet
Bulb
  Wattage
  Type
  Open Circuit
Voltage
  Capacitor
  Short Circuit
Amps
  Ignitor
 
                           
            METAL HALIDE
             
M48
  1500
  CWA
  462
  32-525
  7.3-9.1
     
M47
  1000
  CWA
  425
  24-480
  5.1-6.3
     
M59
  400
  CWA
  305
  24-400
  3.5-4.3
     
M58
  250
  CWA
  310
  15-400
  2.3-2.8
     
M57
  175
  CWA
  295
  10-400
  1.5-1.8
     
                           
                           
            PULSE START
             
                           
M141
  1000
  CWA
  425
  24-480
  5.1-6.3
  ST2002
 
M166
  875
  CWA
  425
  22-460
  3.8-6.4
  ST2002
 
M149
  750
  CWA
  395
  24-480
  3.1-5.2
  ST1003
 
M135
  400
  PS-CWA
  265
  26-330
  3.6-4.5
  ST1001
 
M131
  350
  PS-CWA
  280
  20.5-400
  3.0-3.8
  ST1001
 
M132
  320
  PS-CWA
  270
  19.5-400
  2.8-3.6
  ST1001
 
M138
  250
  PS-CWA
  310
  15-400
  2.3-2.8
  ST1001
 
M136
  200
  PS-CWA
  240
  15-300
  1.9-2.3
  ST1001
 
M102
  150
  HX-HPF
  280
  16-280
  2.1-2.6
  ST1001
 
M90
  100
  HX-HPF
  270
  12-280
  1.3-1.8
  ST1001
 
M98
  70
  HX-HPF
  250
  8-280
  .1-.12
  ST1001
 
M11
  50
  HX-HPF
  250
  .6-280
  .75-.95
  ST1001
 
                           
            MH REACTOR
             
M98
  70
  REACTOR
  277
  8-280
  .85-1.3
     
M110
  50
  REACTOR
  277
  5-280
  .6-.9
     
                           
            HPS
             
                           
S52
  1000
  CWA
  438
  26-525
  6.3-7.7
  ST2002
 
S51
  400
  CWA
  200
  55-240
  6.0-7.4
  ST2002
 
S50
  250
  CWA
  194
  35-240
  3.8-4.7
  ST2000
 
S55
  150
  HX-HPF
  120
  14-280
  3.6-4.7
  ST2001
 
S54
  100
  HX-HPF
  125
  10-280
  2.4-3.2
  ST2001
 
S62
  70
  HX-HPF
  129
  7-280
  1.6-2.2
  ST2001
 
S68
  50
  HX-HPF
  120
  20-120
  1.5-2.2
  ST2001
 
S76
  35
  HX-HPF
  120
  20-120
  .9-1.5
  ST2001
 
Use this chart to find the proper capacitor  and ignitor, for the particular size HID fixture ballast.  There is also listed the open circuit
voltage, which is the operating voltage of  the transformer secondary windings, when not energizing the bulb.. The short circuit amps is
the range that the amp meter should show if testing the secondary of the transformer, by shorting to the common.